Akai S1000 Series Operator's Manual Page 225

  • Download
  • Add to my manuals
  • Print
  • Page
    / 276
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 224
Page 213
Chapter 11: MIDI Function
MIDI Input Filter
Selecting option 3 from the MIDI key menu presents the MIDI
Input Filter screen, which allows specific types of MIDI events to be
either received or ignored by the MPC3000:
===== Sound Generator Input Filter =====
MIDI volume:RECEIVE MIDI vol now:127
Prog change:IGNORE
======= Sequencer Input Filter =========
Event:NOTES
Pass event?:YES Min change:5
Velocity mode:NORMAL Fixed veloc: 64
========================================
There are two sections, the Sound Generator Input Filter and the
Sequencer Input Filter. The fields are:
The Sound Generator Input Filter section:
• The MIDI volume field:
This choice field has two options: RECEIVE and IGNORE. If set to
RECEIVE, incoming MIDI volume messages (controller 7) will
affect the sound generators overall output volume on all outputs. If
set to IGNORE, incoming MIDI volume messages will be ignored.
• The MIDI vol now field:
This field shows the last value of MIDI volume (controller 7)
received. A value of 127 is normal (no attenuation). Any value less
than 127 causes the volume of all outputs to be attenuated from
normal. A VALUE OF ZERO WILL SILENCE ALL AUDIO
OUTPUTS EVEN IF ALL OTHER PARAMETERS ARE SET
CORRECTLY!
• The Prog change field:
This choice field has two options: RECEIVE and IGNORE. If set to
RECEIVE, incoming Program Change messages will automatically
select the active program. (Incoming Program Change messages
above program 24 will select program 24.) If set to IGNORE, incom-
ing Program Change messages will be ignored.
The Sequencer Input Filter section:
• The Event and Pass event? fields:
The Event field is a choice field and can be set to any one of the
following event types: