Chapter 11: MIDI Functions
Page 209
MIDI Input Filter
Selecting option 3 (MIDI input filter) from the MIDI key menu presents the
MIDI Input Filter screen, which allows specific types of MIDI events to be
either received or ignored by the MPC60:
===== Sound Generator Input Filter ====A
MIDI volume:RECEIVE MIDI vol now:127
Prog change:IGNORE
======= Sequencer Input Filter =========
Event:NOTES
Pass event?:YES Min change:5
Velocity mode:NORMAL Fixed veloc: 64
========================================
There are two sections, the Sound Generator Input Filter and the
Sequencer Input Filter. The fields are:
The Sound Generator Input Filter section:
• The MIDI volume field:
This choice field has two options: RECEIVE and IGNORE. If set to
RECEIVE, incoming MIDI volume messages (controller 7) will affect the
sound generator’s overall output volume on all outputs. If set to IGNORE,
incoming MIDI volume messages will be ignored.
• The MIDI vol now field:
This field shows the last value of MIDI volume (controller 7) received. A
value of 127 is normal (no attenuation). Any value less than 127 causes
the volume of all outputs to be attenuated (reduced) from normal. A
VALUE OF ZERO WILL SILENCE ALL AUDIO OUTPUTS EVEN IF ALL
OTHER PARAMETERS ARE SET CORRECTLY!
• The Prog change field:
This choice field has two options: RECEIVE and IGNORE. If set to
RECEIVE, incoming Program Change messages will automatically
select the active program. (Incoming Program Change messages above
program 8 will select program 8.) If set to IGNORE, incoming Program
Change messages will be ignored.