Akai MPC Operator's Manual Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
MPC2500 Operators Manual rev 1.0
50
Chapter 9: Q-Link slider & knob
04. In the High range field and Low range field, set the
upper and lower limit of the slider or knobs.
The value of the controlled parameter is determined
by the value set here. The value depends on the type
of the parameter selected in the Parameter field.
TUNE :
-120 - +120 This controls the sample pitch with “10”
equals a semitone.
LEVEL : 0 –100
This control the sample volume level.
CUTOFF1+2 / CUTOFF1 / CUTOFF2 : -50 - +50
This offsets the cut off frequency of the currently
selected filter. The value set in the PROGRAM mode
is used as 0.
RESO1+2 / RESO1 / RESO2 : -50 - +50
This offsets the resonance of the currently selected filter.
The value set in the PROGRAM mode is used as 0.
LAYER : 0 - 127
This value switches layers instead of Velocity.
ATTACK : 0 – 100
The attack time of the envelope will be replaced
with this value.
DECAY : 0 – 100
The decay time of the envelope will be replaced
with this value.
Note : When you change the LEVEL or the PAN on REAL
TIME by Q-Link slider/knob, some noise may occur depend-
ing on the sound.
Resetting the Q-Link slider / knob value
You can reset (back to the original value) the altered
value of Q-Link slider/knob.
Example : When you control the Tune of the Pad Event
with REAL TIME, the Tune will keep the changed value
after you change the Q-Link slider. If you press the [F5]
(ALL R) key or the [F6] (RESET) key, the changed value
resets to its original value.
[F5] (ALL R) : All parameter changed with REAL
TIME resets to the original value.
[F6] (RESET) :
Only the parameter being displayed in
Slider page resets to the original value.
Recording the slider/knob
value in a sequence
When you use the Q-Link slider/knob while recording a
sequence. the Note Variation data will be recorded into the
track of the sequence.
When the NOTE ON is selected in the Change field,
the value of the Q-Link slider/knob will be recorded
as Note Variation information with the Pad Event.
When the REAL TIME is selected in the Change field,
the value of the Q-Link slider/knob will be recorded
as Q-Link event, independent of the Pad Event.
AFTER key
This key sets the operation of the Q-Link slider/knob, when a
sequences is recorded, the Note Variation data is played back.
The operation of the [AFTER] key is different with “NOTE
ON” or “REAL TIME” .
When the “NOTE ON” is selected,
If the [AFTER] key is OFF, (the LED is off), if you
move the Q-Link slider or knob while playing back
a sequence with Note Variation, the Pad’s Note
Variation is played as recorded. If you hit a Pad
during playback, the Pad that you hit will have
the effect of Q-Link slider or knob.
If the [AFTER] key is ON (the LED is lit.), if you
move the Q-Link slider or knob while playing back
a sequence with Note Variation, the Note Varia-
tion value will be replaced with the current posi-
tion of the Q-Link slider or knob.
When the “REAL TIME” is selected,
If the [AFTER] key is OFF, (the LED is off), if you
move the Q-Link slider or knob while playing back
a sequence with Note Variation, the recorded Pad’s
sound will be changed.
If the [AFTER] key is ON (the LED is lit.), the re-
corded Q-Link Event will be ignoreed and the cur-
rent Q-Link slider/knob position will be used while
playing back a sequence with Note Variation.
While recording a sequence,
If the [AFTER] key is OFF, when you move the Q-
Link slider/knob, the new Q-Link Event will be re-
corded and added to the existing Q-Link Events.
If the [AFTER] key is ON, when you move the Q-
Link slider/knob. The new Q-Link event will be
recorded and will erase any previous Q-Link Events.