Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Value
Item Symbol
Min. Max.
Unit Note
Storage Temperature T
ST
-20 +60 ºC (1)
Operating Ambient Temperature T
OP
0 +50 ºC (1), (2)
Shock (Non-Operating) S
NOP
- 100 G (3), (5)
Vibration (Non-Operating) V
NOP
- 1.0 G (4), (5)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The temperature of panel display area surface should be 0 ºC Min. and 60 ºC Max.
Note (3) 2 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 500 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Storage Range
5
20
60
40
80
-40 -20 0 20 40 60 80
100
90
Temperature (ºC)
Operating Range
Relative Humidity (%RH)
5 / 26
The information described in this technical specification is tentative and it is possible to be changed without prior
notice. Please contact CMO ’s representative while your product design is based on this specification. Version 2.0