Akai MPC 60 Operator's Manual Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 241
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
Chapter 4: Editing Sequences
Page 89
5. The Duration field (D: 96
):
This field shows the note duration in ticks (96 ticks = one
quarter note). The range is 1–9999 ticks.
• The Program Change event
>Program_change Val: 1
The single field, Val, with a range of 1–128, is used to select the MIDI
program number.
• The Pitch Bend event
>Pitch_bend Val:+ 0
The single field, Val, contains the actual numeric value of the pitch bend
event. It is a signed field, with a range from -8192 to 8191.
• The Channel Pressure event
>Channel_pressure Val:127
The single field, Val, has a range of 0–127.
• The Poly Pressure event
>Poly_pressure Note: 60(C.3 ) Val:127
There are three fields:
1. The Note Number field (Note: 60
(C.3 )):
This is the note to which the pressure message applies.
2. The Note Name field (Note: 60<C.3
)):
This is the note name for the note number selected at the left.
This is for display only and cannot be edited.
3. The Value field (Val:127
):
This is the pressure value for the selected note number (0 to
127).
• The System-Exclusive event
>System_exc Size: 1 Byte: 1 Val: 0
There are three fields:
1. The Size field:
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 240 241

Comments to this Manuals