Chapter 9: Saving and Loading From Disk
Page 167
To select a different disk device, choose it in the Disk field, then press
the <Select it>soft key. The options are:
FLOPPY DISK
SCSI DISK PART A
SCSI DISK PART B
SCSI DISK PART C
(and other hard disk partitions if they exist)
When <Select it> is pressed, the previous screen will be redisplayed and
the selected disk device will be active.
Loading a SEQ File (Single Sequence)
If a SEQ file is selected and <Load> is pressed, you’ll see the following
screen, in which you are asked which sequence number to load the
sequence into:
===== Load a Sequence file (.SEQ) =====A
Load into sequence:02-Sequence_name
========================================
<Load it>
Select the sequence number to load the file into, then press <Load it>.
If the file is an MPC60 version 1 or 2 SEQ file
If the SEQ file is a MPC60 version 2 file, additional screens are
presented:
=========== Load V2 SEQ File ==========A
Each drum note's pad assignment must be
converted to a MIDI note number using the
editable table in the next screen. To
standardize note-to-instrument
assignments, use General MIDI numbers.
========================================
<Next screen>