SYSTEM SETUP
GRAB OUT MARK - When a pulse is received, it will mark an OUT point.
RESET BIPHASE - This will reset the biphase receiver.
TOGGLE EXT.TIME - When a pulse is received, it will switch on/off the
external time source.
RECORD REHEARSE - This will switch on/off the record rehearsal
function.
PLAY TRACK - These options allow any of the playback tracks to be
switched on/off by a GPI control. The first GPI command will switch the
track on, the next will switch it off.
RECORD TRACK - These options allow any of the record tracks to be
switched on/off by a GPI control. The first GPI command will switch the
track on, the next will switch it off.
RECORD TRACK ON - These options allow any of the record tracks to
be switched on by a GPI control.
RECORD TRACK OFF - These options allow any of the record tracks to
be switched off by a GPI control.
Pressing the GPO soft key (F1) will take you to the GPO assignment page:
This page allows you to set the parameters for the General Purpose Outputs (GPOs). The
parameters are:
ACTIVE Allows you to select OFF, HIGH or LOW. OFF switches the GPO function
off. HIGH selects that the GPO is normally low (0V) and when the selected
function is activated, the output will be pulled up to the voltage at the
GPO pullup pin. When set to LOW, the GPO is pulled to 0V when the
selected function is activated.
FUNCTION A variety of functions may be applied to the GPOs. These are:
PLAYING - The GPO will change level when PLAY is activated.
STOPPED - The GPO will change level when STOP is activated.
LOCATING - The GPO will change level while locating to a timecode
position.
RECORDING - The GPO will change level when RECORD is activated.
EXT TIMECODE OK - The GPO will change level while external timecode
is being successfully received.