Chapter 12: MIDI Applications
1. Use a MIDI cable to connect the DPS16’s MIDI OUT/THRU connector and the MIDI sequencer’s
MIDI IN connector.
TIP :
A device transmitting MTC (DPS16 in this case) is called an “MTC master”, and a device receiving
MTC (MIDI sequencer in this case) is called an “MTC slave”.
MIDI IN
External MIDI device
(MIDI sequencer, etc.)
MIDI slave
MIDI master
MIDI OUT
MIDI clock
Song Position Pointer
SHUTTLEJOG
DPS16
2. Press the [SETUP] key to recall Setup mode and press the [F3] ( MISC.) key.
3. Move the cursor to the MIDI out/thru field, and turn the [JOG] wheel to set the field to “OUT”.
4.
Press the [F2] ( BEAT) key on the same Setup mode screen.
The DPS16 displays the screen where you can set a beat map (Project’s time signature information).
5.
Move the cursor to the Beat field and turn the [JOG] wheel to set the initial time signature of the
song.
You can set the time signature in the range between 1/4 and 32/32. If the time signature changes during the
song, press the [F6] ( INSERT) key to insert new time signature information, and adjust the position and the
time signature value. (See page 104.)