Akai PDP4294LV1 Service Manual Page 78

  • Download
  • Add to my manuals
  • Print
  • Page
    / 103
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 77
1. Check each unit part of PSU inside with naked eyes.
(capacitor, FET, a kind of IC, resistor)
2. Check FUSE and SW1 (on Normal).
3. Check Output voltage which is converted from AC V
to DC V.
voltage Check (5V, Va, Vs)
When PSU Protection occurred. Check Short
between Y-SUS, Z-SUS B/D .
3. PSU(Power Supply Unit)
Fuse open check
SW1 Normal
Multi-meter Touch point
(5V, Va ,Vs must accord with Module Label)
Vs Voltage ADJ
(Vs : About 180 ~195 V)
Va, 5V(VCC) Voltage ADJ
Va : About 55 ~65 V
5V(VCC) : 5V~5.5V)
4. Trouble shooting.
if not same
Confirm
input voltage
Adjust
voltages
Page view 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 102 103