13
/40
1) This is a path to supply SUSTAIN ,RESET waveform which made
from Y SUSTAIN B/D to panel through SCAN DRIVER IC.
2) Supply a wave form that select Horizontal electrode (Y SUSTAIN electrode)
sequentially.
- potential difference is 0V between GND and Vpp of DRIVER IC
in SUSTAIN period.
- being generated potential difference between GND and Vpp only
in SCAN period.
* In case of 42” V6 use DRIVER IC IC 8 EA (TOP, BOTTOM: each 4EA)