Akai MPC5000 Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 222
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
Sample Editing: TRIM Mode 112
Dividing a Sample Automatically (AUTO)
01. In the 'Sample' field within the TRIM page, select the sample
you wish to edit.
You can set the sample range of your edit by adjusting the start/end points. For
more information about adjusting the start/end points, see 'Setting the Start / End
Points' on page 101.
02. Press [F5] (CHOP).
The Chop Shop window will be displayed.
03. In the 'Mode' field, select 'AUTO'.
Recovery time (0 – 100):
This sets the minimum time between the attack and the next attack. If
you set this time too long, continuous attacks may not be detected.
Select a smaller value when the sample has a lot of attack parts.
Threshold (0 –100):
This sets the detectable level of an attack. The smaller the value, the
more sensitive the detection will be, so if you select a very low value,
everything will 'register' as an attack.
Sensitivity (0 – 100):
This sets the sensitivity used while detecting an attack. Selecting a
smaller value will make the detecting process more sensitive towards
varying attack levels.
04. Press [F5] (DO IT).
The MPC5000 will start dividing the sample, then go to the 'Chop Shop' page. The
MPC5000 divides a sample into several regions by automatically detecting the
attack part of the phrase.
The next step is to adjust the divided regions.
Go to the 'Adjusting the Start / End Point of the Region' section for more information.
Dividing a Sample into Regions of Equal Length (EQUALLY)
01. In the 'Sample' field within the TRIM page, select a sample you
wish to edit.
You can set the sample range you wish to edit by adjusting the start/ end point.
For more information about adjusting the start/end points, see 'Setting the Start /
End Points' on page 101.
02. Press the [F5] (CHOP) button.
The Chop Shop window will be displayed.
03. In the 'Mode' field, select 'EQUALLY'.
Number of Region
Set the number of regions you wish to divide the sample into. Usually,
sixteen is a good start for a single measure loop.
04. Press the [F5] (DO IT).
The MPC5000 will start dividing the sample, and then go to the 'Chop Shop' page.
The MPC5000 will divide a sample into separate regions of equal length
The next step is to adjust the divided regions.
Go to the 'Adjusting the Start/ End Point of the Region' section for more information.
Adjusting the Start / End Point of the Region
A Region is each part of a sample that is divided with the 'AUTO' or
'EQUALLY' feature. You can adjust the start/end point of each region
within the CHOP SHOP Page.
01. After dividing a sample using the 'AUTO' or 'EQUALLY' function,
the CHOP SHOP Page will be displayed.
In the CHOP SHOP Page, hitting Pad 1-12 will trigger the selected region.
Page view 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 221 222

Comments to this Manuals

No comments