Adjusting the master level
You can adjust the level of the headphone and the stereo out by turning the MAIN VOLUME knob. The MAIN
VOLUME changes the analog signal level. This will also adjust the entire level of the MPC1000 digitally.
01. Press the [MODE] key and then the [PAD 10] (OTHER).
It switches to the OTHER mode.
02. Press the [F1] (GLOBAL) key.
The GLOBAL page will be displayed.
03. In the Master level field, set the level.
You will set the digital signal level, which will be sent out to the DA converter. The MPC1000 can output up to
32 sounds simultaneously. There is the great difference in the level when you play single sample and play 32
sounds. If you increase the value in the Mater level field, you can increase the entire level of the MPC1000 to
create more powerful sound with less noise. However, if you playback many sounds at the same time, the
level may be overloaded, which may cause distortion. If you decrease the value in the Master level field, you
can prevent distortion when you play many sounds at the same time. However, you cannot have a good
result in respect to the noise or punch of the sound. Set the appropriate value in the Master level field
depending on the application.
Adjusting the contrast of LCD
You can adjust the contrast of the LCD display by turning the DATA wheel with holding [SHIFT] key. Adjusting the
contrast of LCD can be done in any page.
Initialize to Factory Preset
Various Sample and Sequence settings can be saved to Compact Flash when the file is saved. The global settings
found in the MPC1000 (listed below) are saved to the internal Flash Memory and stored when the MPC1000 is
turned off. You can re-initialize the Factory Preset settings using the following procedure.
01. Turn the MPC1000 on while holding the [ERASE] key.
02. Release the [ERASE] key after the display shows [ MPC1000 (##MB installed)].
Now the MPC1000 is reset to the Factory Preset settings.
The following global settings are stored in the MPC1000 :
Timing Correct (Note value, Swing%)
Click/Metronome (Count in, Rate, In play, In rec)
Step Edit Options (Auto step increment, Duration of recorded notes)
Active track receive channel
Soft thru
Sync in
Sync out
Master level
Sustain pedal to duration
Truncate duration
Tap average
Footswitch 1
Footswitch 2
Autoload
LCD contrast
Other settings